Bernardo de Andrada Pereira, Jennifer N. Lehrman, Anna G.U. Sawa, Piyanat Wangsawatwong, Jakub Godzik, David S. Xu, Jay D. Turner, Brian P. Kelly, Juan S. Uribe
Neurospine 2022;19(3):828-837. Published online September 30, 2022
Objective The high mechanical stress zone at the sudden transition from a rigid to flexible region is involved in proximal junctional kyphosis (PJK) physiopathology. We evaluated the biomechanical performance of polyetheretherketone (PEEK) rods used as a nontraditional long semirigid transition phase from a long-segment metallic rod construct to the nonfused thoracic spine.
Methods Pure moment range of motion (ROM) tests (7.5 Nm) were performed on 7 cadaveric spine segments followed by compression (200 N). Specimens were tested in the following conditions: (1) intact; (2) T10-pelvis pedicle screws and rods (PSRs); and (3) extending the proximal construct to T6 using PEEK rods (PSR+PEEK). T10–11 rod strain, T9 anterolateral bone strain, and T10 screw bending moments were analyzed.
Results At the upper instrumented vertebra (UIV)+1, PSR+PEEK versus PSR significantly decreased ROM in flexion (115%, p = 0.02), extension (104%, p = 0.003), left lateral bending (46%, p = 0.02), and right lateral bending (63%, p = 0.008). Also, at UIV+1, PSR+PEEK versus intact significantly decreased ROM in flexion (111%, p = 0.01) and extension (105%, p = 0.003). The UIV+1 anterior column bone strain was significantly reduced with PSR+PEEK versus PSR during right lateral bending (p = 0.02). Rod strain polarities reversed with PEEK rods in all loading directions except compression.
Conclusion Extending a long-segment construct using PEEK rods caused a decrease in adjacent-level hypermobility as a consequence of long-segment immobilization and also redistributed the strain on the UIV and adjacent levels, which might contribute to PJK physiopathology. Further studies are necessary to observe the clinical outcomes of this technique.
Citations
Citations to this article as recorded by
Evaluation of Screw Loosening in Patients Undergoing Semi-rigid Stabilization with Polyetheretherketone (PEEK) Rods Nimetullah Alper Durmus, Ali Sahin, Sukru Oral, Halil Ulutabanca, Ahmet Kucuk, Rahmi Kemal Koc Indian Journal of Orthopaedics.2026; 60(6): 1537. CrossRef
Proximal Junctional Kyphosis Prevention in Adult Spinal Deformity Surgery: A Technical Review of Tethering and Adjunctive Strategies Paritash Tahmasebpour, Pawel P. Jankowski, Jason Liang, Joshua Lin, Kyriakos D. Chatzis, Peter S. Tretiakov, Spencer Matthews, Louis Boissiere, John F. Burke, Christopher I. Shaffrey, Aaron Hockley, Peter Passias Operative Neurosurgery.2026;[Epub] CrossRef
Relationship Between the Elastic Modulus of the Novel Pedicle Screw-Plate System and Biomechanical Properties Under Osteoporotic Condition: A Power-Law Regression Analysis Based on Parametric Finite Element Simulations Kaibin Wang, Chongyi Wang, Haipeng Si, Yanwei Zhang, Shaowei Sang, Runtong Zhang, Wencan Zhang, Junfei Chen, Chen Liu, Kunpeng Li, Bingtao Hu, Xiangyu Lin, Yunze Feng, Qingyang Fu, Zhihao Kang, Mingyu Xu, Dingxin Zhang, Wanlong Xu, Le Li Computer Methods and Programs in Biomedicine.2025; 265: 108760. CrossRef
Optimizing Surgical Strategies for Preventing Proximal Junctional Complications: A Systematic Review and Meta-analysis of Operative Techniques in Adult Spinal Deformity HyungSub Jin, Kyung-Soo Suk, Byung Ho Lee, Si Young Park, Hak-Sun Kim, Seong-Hwan Moon, Sub-Ri Park, Namhoo Kim, Jae Won Shin, Ji-Won Kwon Neurospine.2025; 22(4): 1012. CrossRef
A Biomechanical Comparison of 2 Different Topping-off Devices and Their Influence on the Sacroiliac Joint Following Lumbosacral Fusion Surgery Wei Fan, Song Yang, Jie Chen, Li-Xin Guo, Ming Zhang Neurospine.2024; 21(1): 244. CrossRef
Application of Transverse Process Hooks at Distal Thoracic Vertebrae in Uppermost Vertebral Instrumentation for Adult Spinal Deformity Surgery: Special Focus on Delayed-Onset Neurologic Deficits Sun-Joon Yoo, Hyun-Jun Jang, Bong Ju Moon, Jeong-Yoon Park, Sung Uk Kuh, Dong-Kyu Chin, Keun-Su Kim, Jun Jae Shin, Yoon Ha, Kyung-Hyun Kim Neurospine.2024; 21(4): 1219. CrossRef
Comparison of Cortical Bone Trajectory to Pedicle-Based Dynamic Stabilization: An Analysis of 291 Patients Chih-Chang Chang, Hsuan-Kan Chang, Chin-Chu Ko, Ching-Lan Wu, Yi-Hsuan Kuo, Tsung-Hsi Tu, Wen-Cheng Huang, Jau-Ching Wu Neurospine.2023; 20(1): 308. CrossRef
Pelvic Incidence–Lumbar Lordosis Mismatch Is Predisposed to Adjacent Segment Degeneration After Single-Level Anterior Lumbar Interbody Fusion: A Retrospective Case-Control Study Sun Geon Yoon, Hyung Chang Lee, Sang-Min Lee Neurospine.2023; 20(1): 301. CrossRef
Objective The lordotic shape of the lumbar spine differs substantially between individuals. Measuring and recording strain during spinal biomechanical tests is an effective method to infer stresses on spinal implants and predict failure mechanisms. The geometry of the spine may have a significant effect on the resultant force distribution, thereby directly affecting rod strain.
Methods Seven fresh-frozen cadaveric specimens (T12-sacrum) underwent standard (7.5 Nm) nondestructive sagittal plane tests: flexion and extension. The conditions tested were intact and pedicle screws and rods (PSR) at L1-sacrum. The posterior right rod was instrumented with strain gauges between L3–4 (index level) and the L5–S1 pedicle screw. All specimens underwent lateral radiographs before testing. Lordotic angles encompassing different levels (L5–S1, L4–S1, L3–S1, L2–S1, and L1–S1) were measured and compared with rod strain. Data were analyzed using Pearson correlation analyses.
Results Strong positive correlations were observed between lordosis and posterior rod strain across different conditions. The L3–S1 lordotic angle in the unloaded intact condition correlated with peak rod strain at L3–4 with PSR during flexion (R = 0.76, p = 0.04). The same angle in the unloaded PSR condition correlated with peak strain in the PSR condition during extension (R = -0.79, p = 0.04). The unloaded intact L2–S1 lordotic angle was significantly correlated with rod strain at L3–4 in the PSR condition during flexion (R = 0.85, p = 0.02) and extension (R = -0.85, p = 0.02) and with rod strain at L5–S1 in the PSR condition during flexion (R = 0.84, p = 0.04).
Conclusion Lordosis measured on intact and instrumented conditions has strong positive correlations with posterior rod strain in cadaveric testing.
Citations
Citations to this article as recorded by
Machine learning models for predicting treatment outcomes in chronic non-specific back pain patients undergoing lumbar extension traction Ibrahim M. Moustafa, Dilber Uzun Ozsahin, Mubarak Taiwo Mustapha, Shima Zadeh, Iman Khowailed, Paul A. Oakley, Deed E. Harrison Scientific Reports.2026;[Epub] CrossRef
Acute pelvic fixation failure in adult spinal deformity-risk factors and tips and pearls for management Kari Odland, Christopher T. Martin Seminars in Spine Surgery.2026; 38(2): 101254. CrossRef
Impact of transforaminal lumbar interbody fusion on rod load: a comparative biomechanical analysis between a cadaveric instrumentation and simulated bone fusion Maximilian Heumann, Chencheng Feng, Lorin M. Benneker, Maarten Spruit, Christian Mazel, Jan Buschbaum, Boyko Gueorguiev, Manuela Ernst Medical Engineering & Physics.2025; 139: 104339. CrossRef
Comparison of posterior trans-intervertebral osteotomy and pedicle Subtraction osteotomy for the correction of thoracolumbar kyphotic deformity secondary to ankylosing spondylitis Lijin Zhou, Honghao Yang, Jie Wang, Yiqi Zhang, Yunsheng Wang, Yong Hai Journal of Orthopaedic Surgery and Research.2025;[Epub] CrossRef
Analysis of the association between lumbar paraspinal muscle atrophy, facet joint degeneration, and degenerative lumbar scoliosis Jiangkai Yu, Cong Zhang, Yan Zhou, Chengming Li European Journal of Medical Research.2025;[Epub] CrossRef
Biomechanical evaluation of multi-rod constructs to stabilize an S1 pedicle subtraction osteotomy (PSO): a finite element analysis Niloufar Shekouhi, Sudharshan Tripathi, Vijay K. Goel, Alekos A. Theologis Spine Deformity.2024; 12(2): 313. CrossRef
Torque forces of expandable titanium vertebral body replacement cages during expansion and subsidence in the osteoporotic lumbar spine Krishnan Sircar, Maximilian Weber, Sebastian G. Walter, Nadine Ott, Andreas Prescher, Peer Eysel, Nikolaus Kernich Clinical Biomechanics.2024; 114: 106239. CrossRef
How common is acute pelvic fixation failure after adult spine surgery? A single-center study of 358 patients Nathan J. Lee, Paul J. Park, Varun Puvanesarajah, William E. Clifton, Kevin Kwan, Cole R. Morrissette, Jaques L. Williams, Michael W. Fields, Eric Leung, Fthimnir M. Hassan, Peter D. Angevine, Christopher E. Mandigo, Joseph M. Lombardi, Zeeshan M. Sardar, Journal of Neurosurgery: Spine.2023; 38(1): 91. CrossRef
Cross-link augmentation enhances CFR-PEEK short fixation in lumbar metastasis stabilization Simone Borrelli, Giovanni Putame, Alberto L. Audenino, Cristina Bignardi, Andrea Ferro, Stefano Marone, Mara Terzini Frontiers in Bioengineering and Biotechnology.2023;[Epub] CrossRef
Radiological Outcomes of Unilateral Laminotomy for Bilateral Decompression in Lumbar Spinal Stenosis With and Without Discectomy Hyun-Seo Cho, Se-Hoon Kim, Jeong Su Han, Bum-Joon Kim World Neurosurgery.2023; 175: e1307. CrossRef
Mechanical Failure After Total En Bloc Spondylectomy and Salvage Surgery Shin Won Kwon, Chun Kee Chung, Young Il Won, Woon Tak Yuh, Sung Bae Park, Seung Heon Yang, Chang Hyun Lee, John M. Rhee, Kyoung-Tae Kim, Chi Heon Kim Neurospine.2022; 19(1): 146. CrossRef
Incidence, mechanism, and protective strategies for 2-year pelvic fixation failure after adult spinal deformity surgery with a minimum six-level fusion Nathan J. Lee, Gerard Marciano, Varun Puvanesarajah, Paul J. Park, William E. Clifton, Kevin Kwan, Cole R. Morrissette, Jaques L. Williams, Michael Fields, Fthimnir M. Hassan, Peter D. Angevine, Christopher E. Mandigo, Joseph M. Lombardi, Zeeshan M. Sarda Journal of Neurosurgery: Spine.2022; : 1. CrossRef