The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Neurospine. 2024;21(1):352-360.   Published online January 29, 2024
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
The Efficacy of Cervical Pedicle Screw Is Enhanced When Used With 5.5-mm Rods for Metastatic Cervical Spinal Tumor Surgery
Neurospine. 2024;21(1):352-360.   Published online January 29, 2024
Close
Objective
The cervical spine presents challenges in treating metastatic cervical spinal tumors (MCSTs). Although the efficacy of cervical pedicle screw placement (CPS) has been well established, its use in combination with 5.5-mm rods for MCST has not been reported. This study aimed to evaluate the efficacy of CPS combined with 5.5-mm rods in treating MCST and compare it with that of CPS combined with traditional 3.5-mm rods.
Methods
This retrospective study analyzed 58 patients with MCST who underwent posterior cervical spinal fusion surgery by a single surgeon between March 2012 and December 2022. Data included demographics, surgical details, imaging results, numerical rating scale score for neck pain, Eastern Cooperative Oncology Group performance status, and Spine Oncology Study Group Outcomes Questionnaire responses.
Results
Preoperative Spinal Instability Neoplastic Scores were significantly higher in the 5.5-mm rod group. Greater kyphotic changes in the index vertebra were observed in the 3.5-mm rod group. Neck pain reduction was significantly better in the 5.5-mm rod group.
Conclusion
CPS with 5.5-mm rods provides superior biomechanical stability and effectively resists forward bending momentum in posterior MCST fusion surgery. These findings support the use of 5.5-mm rods to enhance surgical outcomes.

Citations

Citations to this article as recorded by  Crossref logo
  • Anterior Corpectomy Versus Posterior Pedicle Screw Fixation With 5.5-mm Rods for Metastatic Spinal Tumor Located in the Cervicothoracic Junction
    Sun Woo Jang, Hong Kyung Shin, Sang Ryong Jeon, Sung Woo Roh, Danbi Park, Chongman Kim, Jin Hoon Park
    Neurospine.2025; 22(2): 603.     CrossRef
  • The efficacy of 5.5-mm diameter rods combined with cervical pedicle screws for the treatment of challenging spinal disease in cervicothoracic junction: Is it a game-changer?
    Younggyu Oh, Subum Lee, Sang Hyub Lee, Danbi Park, Chongman Kim, Sun Woo Jang, Jin Hoon Park
    Medicine.2025; 104(36): e44369.     CrossRef
  • Verification, validation, and uncertainty quantification of finite element analysis results for pedicle screw assemblies under ASTM F1717 flexion and extension testing
    On Sim, Byeong Cheol Jeong, Chiseung Lee
    Frontiers in Bioengineering and Biotechnology.2025;[Epub]     CrossRef
  • A Complete Facet Resection and Cervical Pedicle Screw Placement Enhances Both Gross Total Resection and Motion Preservation for the Cervical Spinal Dumbbell Tumor
    Sungsoo Bae, Dae-Jean Jo, Sun Woo Jang, Danbi Park, Sang Hyub Lee, Jinuk Kim, Chongman Kim, Jin Hoon Park
    World Neurosurgery.2024; 192: e486.     CrossRef
  • 6,133 View
  • 140 Download
  • 4 Web of Science
  • 4 Crossref