Objective Our study aimed to compare the posterior interposition technique against the posterolateral transosseous technique in the same cadaver specimens.
Methods Computer and cadaver models of 2 fixation techniques were developed. The computer model was constructed to analyze bone volume removed during implant placement and the bony surface area available for fusion. The cadaver model included quasi-static multidirectional bending flexibility and dynamic fatigue loading. Relative motions between the sacrum and ilium were measured intact, after joint destabilization, after fixation with direct-posterior and posterolateral techniques, and after 18,500 cycles of fatigue loading. Relative positions between each implant and the sacrum and ilium were measured after fixation and fatigue loading to ascertain the quality of the bone-implant interface. The 2 techniques were randomized to the left and right sacroiliac joints of the same cadavers.
Results The posterior interposition technique removed less bone volume and facilitated a larger surface area available for bony fusion. Posterior interposition significantly reduced the nutation/counternutation motion of the sacroiliac joint (42% ± 8%) and reduced it more than the posterolateral transosseous technique (14% ± 4%). Upon fatigue loading, the posterior interposition implant maintained the bone-implant interface across all specimens, while the posterolateral transosseous implant migrated or subsided in 20%–50% of specimens.
Conclusion Posterior interposition fixation of the sacroiliac joint reduces joint motion. The amount of fixation from the posterior technique is superior and more durable than the amount of fixation achieved by the posterolateral technique.
Citations
Citations to this article as recorded by
Sacroiliac joint fixation with a posterior intra-articular implant versus a posterolateral transiliac implant: A biomechanical comparison Connor Huxman, Joshua Tandio, Douglas Beall, Sarah Mayer, Adam Rogers, Thomas P. Hedman, Jonathan A. Hyde, Usman Latif, Richard Oluwatodimu Raji, Jeremi M. Leasure North American Spine Society Journal (NASSJ).2026; 26: 100871. CrossRef
Best practices for the LinQ sacroiliac joint stabilization procedure for the treatment of sacroiliac joint disorders Timothy Deer, Anuj Shah, David Reece, Chau M. Vu, Siddardth Umapathy, Harman Chopra, Colin Mark Buday, Rosa A. Garcia, Johnson S. Ho, Robin Mata, Christopher M. Lam, Christopher L. Robinson, Lucas Bracero, Mateusz Graca, Casey Grillo, Ashley G. Comer, Kas Pain Management.2026; 16(7): 809. CrossRef
A Retrospective, Multicenter Analysis of a Novel Sacroiliac Joint Fusion Device on Safety and Efficacy at 12 Months: Access Study Michael J. Dorsi, Pankaj Mehta, Chau Vu, Angel Boev, Ashley Bailey-Classen, Greg Moore, David Reece, Alaa Abd-Elsayed, Steven Falowski, Jason E. Pope Healthcare.2025; 13(13): 1544. CrossRef
Optimal screw insertion trajectory for sacroiliac joint fusion surgery: An evolutionary and growth process perspective on the sacroiliac joint Daisuke Kurosawa, Kouji Sanaka, Eiichi Murakami Medical Hypotheses.2025; 202: 111730. CrossRef
Objective Recent studies indicate that 3 morphological types of atlanto-occipital joint (AOJ) exist in the craniovertebral junction and are associated with type II basilar invagination (BI) and atlanto-occipital instability. However, the actual biomechanical effects remain unclear. This study aims to investigate biomechanical differences among AOJ types I, II, and III, and provide further evidence of atlanto-occipital instability in type II BI.
Methods Models of bilateral AOJ containing various AOJ types were created, including I-I, I-II, II-II, II-III, and III-III models, with increasing AOJ dysplasia across models. Then, 1.5 Nm torque simulated cervical motions. The range of motion (ROM), ligament and joint stress, and basion-dental interval (BDI) were analyzed.
Results The C0–1 ROM and accompanying rotational ROM increased progressively from model I-I to model III-III, with the ROM of model III-III showing increases between 27.3% and 123.8% indicating ultra-mobility and instability. In contrast, the C1–2 ROM changes were minimal. Meanwhile, the stress distribution pattern was disrupted; in particular, the C1 superior facet stress was concentrated centrally and decreased substantially across the models. The stress on the C0–1 capsule ligament decreased during cervical flexion and increased during bending and rotating loading. In addition, BDI gradually decreased across the models. Further analysis revealed that the dens showed an increase of 110.1% superiorly and 11.4% posteriorly, indicating an increased risk of spinal cord impingement.
Conclusion Progressive AOJ incongruity critically disrupts supportive tissue loading, enabling incremental atlanto-occipital instability. AOJ dysplasia plays a key biomechanical role in the pathogenesis of type II BI.
Objective Cervical hybrid surgery optimizes the use of cervical disc arthroplasty (CDA) and zero-profile (ZOP) devices in anterior cervical discectomy and fusion (ACDF) but lacks uniform combination and biomechanical standards, especially in revision surgery (RS). This study aimed to investigate the biomechanical characteristics of adjacent segments of the different hybrid RS constructs in ACDF RS.
Methods An intact 3-dimensional finite element model generated a normal cervical spine (C2–T1). This model was modified to the primary C5–6 ACDF model. Three RS models were created to treat C4–5 adjacent segment degeneration through implanting cages plus plates (Cage-Cage), ZOP devices (ZOP-Cage), or Bryan discs (CDA-Cage). A 1.0-Nm moment was applied to the primary C5–6 ACDF model to generate total C2–T1 range of motions (ROMs). Subsequently, a displacement load was applied to all RS models to match the total C2–T1 ROMs of the primary ACDF model.
Results The ZOP-Cage model showed lower biomechanical responses including ROM, intradiscal pressure, maximum von Mises stress in discs, and facet joint force in adjacent segments compared to the Cage-Cage model. The CDA-Cage model exhibited the lowest biomechanical responses and ROM ratio at adjacent segments among all RS models, closely approached or lower than those in the primary ACDF model in most motion directions. Additionally, the maximum von Mises stress on the C3–4 and C6–7 discs increased in the Cage-Cage and ZOP-Cage models but decreased in the CDA-Cage model when compared to the primary ACDF model.
Conclusion The CDA-Cage construct had the lowest biomechanical responses with minimal kinematic change of adjacent segments. ZOP-Cage is the next best choice, especially if CDA is not suitable. This study provides a biomechanical reference for clinical hybrid RS decision-making to reduce the risk of ASD recurrence.
Citations
Citations to this article as recorded by
Biomechanical Changes in Kyphotic Cervical Spine After Anterior Cervical Discectomy and Fusion with Different Degrees of Correction Hongyu Chen, Xu Ma, Shengfa Pan, Li Zhang, Yanbin Zhao, Xin Chen, Yu Sun, Feifei Zhou Bioengineering.2025; 12(3): 213. CrossRef
Midterm outcomes of revision anterior fusion versus cervical disc arthroplasty in patients with prior single-level anterior cervical fusion Justin J. Turcotte, Jane C. Brennan, Andrea H. Johnson, Chad M. Patton The Spine Journal.2025; 25(11): 2422. CrossRef
Comparison of Hybrid Surgery and Two-Level ACDF in Treating Consecutive Cervical Degenerative Disc Disease: A Systematic Review and Meta-Analysis Yihan Yang, Weishi Liang, Duan Sun, Bo Han, Zhangfu Li, Yeqiu Xu, Peng Yin, Xianjun Qu, Yong Hai Global Spine Journal.2025; 15(8): 3953. CrossRef
Is zero-profile fixation safe in consecutive two-level anterior cervical discectomy and fusion with partial uncinate resection? A finite element analysis Ning Wu, Jiarui Zhang, Zhilin Ge, Rueishiuan Jiang, Lingxi Cai, Siqi Zhang, Jiying Wei, Kai Tang BMC Musculoskeletal Disorders.2025;[Epub] CrossRef
Finite element analysis of two‐level discontinuous cervical hybrid revision surgery strategy to reduce biomechanical responses of adjacent segments Weishi Liang, Duan Sun, Bo Han, Yihan Yang, Peng Yin, Yong Hai JOR SPINE.2024;[Epub] CrossRef
Objective This study aimed to evaluate the effects of 2 endoscopic spine surgeries on the biomechanical properties of normal and osteoporotic spines.
Methods Based on computed tomography images of a healthy adult volunteer, 6 finite element models were created. After validating the normal intact model, a concentrated force of 400 N and a moment of 7.5 Nm were exerted on the upper surface of L3 to simulate 6 physiological activities of the spine. Five types of indices were used to assess the biomechanical properties of the 6 models, range of motion (ROM), maximum displacement value, intervertebral disc stress, maximum stress value, and articular protrusion stress, and by combining them with finite element stress cloud.
Results In normal and osteoporotic spines, there was no meaningful change in ROM or disc stress in the 2 surgical models for the 6 motion states. Model N1 (osteoporotic percutaneous transforaminal endoscopic discectomy model) showed a decrease in maximum displacement value of 20.28% in right lateral bending. Model M2 (unilateral biportal endoscopic model) increased maximum displacement values of 16.88% and 17.82% during left and right lateral bending, respectively. The maximum stress value of L4–5 increased by 11.72% for model M2 during left rotation. In addition, using the same surgical approach, ROM, maximum displacement values, disc stress, and maximum stress values were more significant in the osteoporotic model than in the normal model.
Conclusion In both normal and osteoporotic spines, both surgical approaches were less disruptive to the physiologic structure of the spine. Furthermore, using the same endoscopic spine surgery, normal spine biomechanical properties are superior to osteoporotic spines.
Citations
Citations to this article as recorded by
The Biomechanical Landscape of Lumbar Disc Herniation: Mechanobiological Insights Into Injury and Regeneration Gianluca Vadala, Fabrizio Russo, In-Ho Han, Amit Jain, Javad Tavakoli Neurospine.2026; 23(1): 159. CrossRef
Biomechanical analysis of the interlaminar dynamic stabilization system (IntraSPINE) in unilateral biportal endoscopic discectomy for huge lumbar disc herniation: a finite element study Zhiwu Zhang, Jiashen Shao, Shuning Liu, Hai Meng, Zihan Fan, Jisheng Lin, Yong Yang, Qi Fei BMC Musculoskeletal Disorders.2026;[Epub] CrossRef
Biomechanical analysis of lumbar oblique manipulation for lumbar disc herniation with different protrusion subtypes Linling Zhang, Zhen Deng, Xuanzong Zhang, Kuan Wang, Maohua Lin, Zhongxiang Yu, Hongsheng Zhan, Yongfang Zhao, Frank Vrionis, Huihao Wang Mechanobiology in Medicine.2026; 4(2): 100188. CrossRef
Altered distribution of intervertebral disc degeneration in degenerative thoracolumbar kyphosis: A retrospective clinical study and finite element analysis Ruifeng Xun, Kangkang Wang, Wanmei Yang, Ao Ding, Jian Wang, Ji Li, Wei Zhang, Xilong Cui, Haiyang Yu Medicine.2026; 105(28): e49770. CrossRef
Cost-effectiveness analysis of extended endoscopic lumbar foraminotomy (EELF) and transforaminal lumbar interbody fusion (TLIF): a prospective observational study Jun-Hoe Kim, Hangeul Park, Chang-Hyun Lee, Chi Heon Kim Scientific Reports.2025;[Epub] CrossRef
Far-Lateral Transforaminal Unilateral Biportal Endoscopic Lumbar Discectomy for Upper Lumbar Disc Herniations Jin Seop Hwang, Sang Hyub Lee, Dain Jeong, Jae-Won Jang, Yong Eun Cho, Dong-Geun Lee, Choon Keun Park, Chung Kee Chough Neurospine.2025; 22(1): 14. CrossRef
Evidence-Based Clinical Practice Guidelines for Patients With Lumbar Disc Herniation With Radiculopathy in South Korea Jong Joo Lee, Min Cheol Chang, Dong Ah Shin, Jin Hoon Park, Miyoung Choi, Hyung-Youl Park, In Soo Kim, Jung-Kil Lee, Chung-Kee Chough, Seung Hwan Yoon, Seong-Soo Choi, Sung-Woo Choi Neurospine.2025; 22(2): 366. CrossRef
Impact of BMI, osteoporosis, and disc degeneration on post-UBE lumbar stability: a finite element analysis of nonlinear synergistic effects Jingbo Ma, Tusheng Li, Rigbat Rozi, Jiaheng Han, Qiang Jiang, Hanshuo Zhang, Xuyan Song, Guotong Zhao, Yu Ding Frontiers in Bioengineering and Biotechnology.2025;[Epub] CrossRef
Biomechanical changes in lumbar intervertebral discs after percutaneous endoscopic transforaminal discectomy surgery at different Body Mass Index (BMI) categories Xiaohai Zhang, Jinghui Lin, Chen Liu, Shuangtao Xue, Mengying Wu, Zongsheng Yin Journal of Orthopaedic Surgery and Research.2024;[Epub] CrossRef
Bernardo de Andrada Pereira, Jennifer N. Lehrman, Anna G.U. Sawa, Piyanat Wangsawatwong, Jakub Godzik, David S. Xu, Jay D. Turner, Brian P. Kelly, Juan S. Uribe
Neurospine 2022;19(3):828-837. Published online September 30, 2022
Objective The high mechanical stress zone at the sudden transition from a rigid to flexible region is involved in proximal junctional kyphosis (PJK) physiopathology. We evaluated the biomechanical performance of polyetheretherketone (PEEK) rods used as a nontraditional long semirigid transition phase from a long-segment metallic rod construct to the nonfused thoracic spine.
Methods Pure moment range of motion (ROM) tests (7.5 Nm) were performed on 7 cadaveric spine segments followed by compression (200 N). Specimens were tested in the following conditions: (1) intact; (2) T10-pelvis pedicle screws and rods (PSRs); and (3) extending the proximal construct to T6 using PEEK rods (PSR+PEEK). T10–11 rod strain, T9 anterolateral bone strain, and T10 screw bending moments were analyzed.
Results At the upper instrumented vertebra (UIV)+1, PSR+PEEK versus PSR significantly decreased ROM in flexion (115%, p = 0.02), extension (104%, p = 0.003), left lateral bending (46%, p = 0.02), and right lateral bending (63%, p = 0.008). Also, at UIV+1, PSR+PEEK versus intact significantly decreased ROM in flexion (111%, p = 0.01) and extension (105%, p = 0.003). The UIV+1 anterior column bone strain was significantly reduced with PSR+PEEK versus PSR during right lateral bending (p = 0.02). Rod strain polarities reversed with PEEK rods in all loading directions except compression.
Conclusion Extending a long-segment construct using PEEK rods caused a decrease in adjacent-level hypermobility as a consequence of long-segment immobilization and also redistributed the strain on the UIV and adjacent levels, which might contribute to PJK physiopathology. Further studies are necessary to observe the clinical outcomes of this technique.
Citations
Citations to this article as recorded by
Evaluation of Screw Loosening in Patients Undergoing Semi-rigid Stabilization with Polyetheretherketone (PEEK) Rods Nimetullah Alper Durmus, Ali Sahin, Sukru Oral, Halil Ulutabanca, Ahmet Kucuk, Rahmi Kemal Koc Indian Journal of Orthopaedics.2026; 60(6): 1537. CrossRef
Proximal Junctional Kyphosis Prevention in Adult Spinal Deformity Surgery: A Technical Review of Tethering and Adjunctive Strategies Paritash Tahmasebpour, Pawel P. Jankowski, Jason Liang, Joshua Lin, Kyriakos D. Chatzis, Peter S. Tretiakov, Spencer Matthews, Louis Boissiere, John F. Burke, Christopher I. Shaffrey, Aaron Hockley, Peter Passias Operative Neurosurgery.2026;[Epub] CrossRef
Relationship Between the Elastic Modulus of the Novel Pedicle Screw-Plate System and Biomechanical Properties Under Osteoporotic Condition: A Power-Law Regression Analysis Based on Parametric Finite Element Simulations Kaibin Wang, Chongyi Wang, Haipeng Si, Yanwei Zhang, Shaowei Sang, Runtong Zhang, Wencan Zhang, Junfei Chen, Chen Liu, Kunpeng Li, Bingtao Hu, Xiangyu Lin, Yunze Feng, Qingyang Fu, Zhihao Kang, Mingyu Xu, Dingxin Zhang, Wanlong Xu, Le Li Computer Methods and Programs in Biomedicine.2025; 265: 108760. CrossRef
Optimizing Surgical Strategies for Preventing Proximal Junctional Complications: A Systematic Review and Meta-analysis of Operative Techniques in Adult Spinal Deformity HyungSub Jin, Kyung-Soo Suk, Byung Ho Lee, Si Young Park, Hak-Sun Kim, Seong-Hwan Moon, Sub-Ri Park, Namhoo Kim, Jae Won Shin, Ji-Won Kwon Neurospine.2025; 22(4): 1012. CrossRef
A Biomechanical Comparison of 2 Different Topping-off Devices and Their Influence on the Sacroiliac Joint Following Lumbosacral Fusion Surgery Wei Fan, Song Yang, Jie Chen, Li-Xin Guo, Ming Zhang Neurospine.2024; 21(1): 244. CrossRef
Application of Transverse Process Hooks at Distal Thoracic Vertebrae in Uppermost Vertebral Instrumentation for Adult Spinal Deformity Surgery: Special Focus on Delayed-Onset Neurologic Deficits Sun-Joon Yoo, Hyun-Jun Jang, Bong Ju Moon, Jeong-Yoon Park, Sung Uk Kuh, Dong-Kyu Chin, Keun-Su Kim, Jun Jae Shin, Yoon Ha, Kyung-Hyun Kim Neurospine.2024; 21(4): 1219. CrossRef
Comparison of Cortical Bone Trajectory to Pedicle-Based Dynamic Stabilization: An Analysis of 291 Patients Chih-Chang Chang, Hsuan-Kan Chang, Chin-Chu Ko, Ching-Lan Wu, Yi-Hsuan Kuo, Tsung-Hsi Tu, Wen-Cheng Huang, Jau-Ching Wu Neurospine.2023; 20(1): 308. CrossRef
Pelvic Incidence–Lumbar Lordosis Mismatch Is Predisposed to Adjacent Segment Degeneration After Single-Level Anterior Lumbar Interbody Fusion: A Retrospective Case-Control Study Sun Geon Yoon, Hyung Chang Lee, Sang-Min Lee Neurospine.2023; 20(1): 301. CrossRef
Objective Anterior-only reconstructions for cervical multilevel corpectomies are prone to fail under continuous mechanical loading. This study sought to define the mechanical characteristics of different constructs in reducing a range of motion (ROM) of the 3-column destabilized cervical spine, including posterior cobalt-chromium (CoCr)-rods, outrigger-rods (OGR), and a novel triple rod construct using lamina screws (6S3R). The clinical implications of biomechanical findings are discussed in depth from the perspective of the challenges surgeons face cervical deformity correction.
Methods Three-column deficient cervical spinal models were produced based on reconstructed computed tomography scans. The corpectomy defect between C3 and C7 end-level vertebrae was restored with anterior titanium (Ti) mesh-cage. The ROM was evaluated in a customized 6-degree of freedom spine tester. Tests were performed with different rod materials (Ti vs. CoCr), varying diameter rods (3.5 mm vs. 4.0 mm), with and without anterior plating, and using different construct patterns: bilateral rod fixation (standard-group), OGRgroup, and 6S3R-Group. Construct stability was expressed in changes and differences of ROM (°).
Results The largest reduction of ROM was noticed in the 6S3R-group compared to the standard- and the OGR-group. All differences observed were emphasized with an increasing number of corpectomy levels and if anterior plating was not added. For all simulated 1-, 2-, and 3-level corpectomy constructs, the OGR-group revealed decreased ROM for all motion directions compared to the standard-group. An increase of construct stiffness was also recorded for increased rod diameter (4.0 mm) and stiffer rod material (CoCr), though these effects lacked behind the more advanced construct pattern.
Conclusion A novel reconstructive technique, the 6S3R-construct, was shown to outperform all other constructs and might resemble a new standard of reference for advanced posterior fixation.
Citations
Citations to this article as recorded by
Biomechanical Impact of Splint Rods in Posterior Cervicothoracic Fixation: A Finite Element Analysis Ian Polyzois, Jaskaran Singh, Sara Gustafson, Trevor Gascoyne, Michael Goytan Global Spine Journal.2026; 16(2): 1259. CrossRef
C1 Posterior Arch Screws for the Additional Reinforcement of Upper Cervical Spine Fixation: Surgical Technique and Preliminary Case Series Guanyi Liu, Jing Wang, Lihua Hu, Miao Zhu, Jiayu Zhang, Weihu Ma, Yong Hu, Qing Li World Neurosurgery.2025; 195: 123680. CrossRef
Triple-rod fixation with laminar screws for three-column cervical spine injury in ankylosing spondylitis: A case report Saurabh Rawall, Sean Taylor, Sakthivel Rajaram Journal of Clinical Orthopaedics and Trauma.2025; 67: 103066. CrossRef
Application of deformity principles in the management of spinal neoplasms: A Primer Zach Pennington, Joseph H Schwab, Sheng-fu Larry Lo, C. Rory Goodwin, Matthew L Goodwin, Matthew Colman, Raphaële Charest-Morin, Nicolas Dea, Daniel Lubelski, Ali Ozturk, Jacob M. Buchowski, Wende Gibbs, Wesley Hsu, Ajit Krishnaney, Ilya Laufer, Mohamed M North American Spine Society Journal (NASSJ).2025; 23: 100779. CrossRef
Posterior cervical spinal fusion in the pediatric population using modern adult instrumentation — clinical outcome and safety Alexander Spiessberger, Peter O. Newton, William Mackenzie, Amer Samdani, Firoz Miyanji, Joshua Pahys, Suken Shah, Paul Sponseller, Mark Abel, Jonathan Phillips, Michelle Marks, Burt Yaszay Child's Nervous System.2023; 39(6): 1573. CrossRef
Mechanical Failure After Total En Bloc Spondylectomy and Salvage Surgery Shin Won Kwon, Chun Kee Chung, Young Il Won, Woon Tak Yuh, Sung Bae Park, Seung Heon Yang, Chang Hyun Lee, John M. Rhee, Kyoung-Tae Kim, Chi Heon Kim Neurospine.2022; 19(1): 146. CrossRef
Surgical Strategies and Perioperative Considerations for Cervical Deformity With Cerebral Palsy: A Comprehensive Review of the Literature Hyung Cheol Kim, Sung Han Oh, Jae Keun Oh, Yoon Ha Neurospine.2022; 19(4): 868. CrossRef
Factors Affecting Postoperative Complications and Outcomes of Cervical Spondylotic Myelopathy with Cerebral Palsy : A Retrospective Analysis Hyung Cheol Kim, Hyeongseok Jeon, Yeong Ha Jeong, Sangman Park, Seong Bae An, Jeong Hyun Heo, Dong Ah Shin, Seong Yi, Keung Nyun Kim, Yoon Ha, Sung-Rae Cho Journal of Korean Neurosurgical Society.2021; 64(5): 808. CrossRef
Commentary on “Emerging Technologies in the Treatment of Adult Spinal Deformity” Seung-Jae Hyun Neurospine.2021; 18(3): 428. CrossRef
To describe the biomechanically relevant anatomy of the Axis vertebra and the load transfer patterns within the bone, and on that basis, to postulate its mechanism of injury, a literature review was conducted of the anatomy and biomechanics of Axis fractures. Two hypotheses have been presented: the internal gear hypothesis and the leaf spring hypothesis. Both are based on the trabecular anatomy of the vertebra and its load transmission patterns. The relationship of the Axis with Hangman’s injury is also discussed. According to the leaf spring hypothesis, the C2 pedicle corresponds to the shackle in the assembly and constitutes the weak link. The trabecular architecture of the Axis is such that the primary compression of the trabeculae is directed from the superior facet to the C2–3 endplate, with few trabeculae directed to the inferior facet. Along with the trabecular void in this area, this renders the isthmus vulnerable to trauma. The isthmus of the Axis is biomechanically susceptible to injury due to its unique anatomy in relation to the whole cervical spine and the internal load transmission patterns of the bone. The author suggests that in the flexion type of Hangman’s injury, the C1–2 posterior ligaments are disrupted and need to be addressed.
Citations
Citations to this article as recorded by
Understanding cervical spine instability: a finite element study on atypical hangman’s fractures Dávid Danka, Imre Bojtár Computer Methods in Biomechanics and Biomedical Engineering.2026; 29(4): 930. CrossRef
Superior articular facet angulation of the axis vertebra in a South African population sample using an osteological analysis Shahed Nalla, Isabel Harmse, Juan A. Sanchis-Gimeno, Juan José Valenzuela-Fuenzalida, Glen J. Paton Translational Research in Anatomy.2026; 43: 100493. CrossRef
Biomechanical evaluation of the novel assembled internal fixed system in C2–C3 anterior cervical discectomy and fusion: a finite element analysis Hu Chen, Hao Sun, Lu Cao, Hong Xia, Qiang Tu Journal of Orthopaedic Surgery and Research.2024;[Epub] CrossRef
Hangman’s Fractures: A Review of Current Concepts in Evaluation and Management Joshua Mizels, James W. Connelly, Nicholas Spina, Brandon Lawrence, Brian A. Karamian Clinical Spine Surgery.2024; 37(9): 365. CrossRef
Detailed observation of anatomical location and pattern in Hangman’s fracture based on computed tomography three-dimensional reconstruction Guangzhou Li, Qing Wang Journal of Orthopaedic Surgery and Research.2023;[Epub] CrossRef
The participation of basolateral amygdala in the efficacy of acupuncture with deqi treating for functional dyspepsia Ruirui Sun, Zhaoxuan He, Peihong Ma, Shuai Yin, Tao Yin, Xiaoyan Liu, Jin Lu, Yuzhu Qu, Tingting Zhang, Liuyang Huang, Xueling Suo, Du Lei, Qiyong Gong, Fanrong Liang, Fang Zeng Brain Imaging and Behavior.2021; 15(1): 216. CrossRef
Efficiency of minimal oblique resection of the uncinate process during an anterior cervical discectomy and fusion Byoung Hun Lee, Jong Hwa Park, Jong Young Lee, Hong Jun Jeon, Seung-Woo Park Medicine.2021; 100(31): e26790. CrossRef
Anterior retropharyngeal cage distraction with atlantoaxial plate-screw fixation for basilar invagination with atlantoaxial dislocation Sushil Patkar Neurosurgical Focus: Video.2020; 3(1): V11. CrossRef