Skip to main navigation Skip to main content
  • E-Submission
  • Contact us

NS : Neurospine

OPEN ACCESS
ABOUT
BROWSE ARTICLES
FOR CONTRIBUTORS

Articles

Page Path

Original Article

Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study

Neurospine 2021;18(4):839-844.
Published online: December 31, 2021

1Department of Spine Surgery, Beijing Jishuitan Hospital, Beijing, China

2Beijing Key Laboratory of Robotic Orthopaedics, Beijing, China

Corresponding Author Wei Tian https://orcid.org/0000-0002-0132-3392 Department of Spine Surgery, Beijing Jishuitan Hospital, No. 31, Xinjiekou East St, Xicheng District, Beijing 100035, China Email: tianwei_spine@sina.com

Qi Zhang and Ming-Xing Fan are co-first authors of this study.

• Received: April 13, 2021   • Revised: June 6, 2021   • Accepted: July 9, 2021

Copyright © 2021 by the Korean Spinal Neurosurgery Society

This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

  • 9,686 Views
  • 156 Download
  • 28 Web of Science
  • 29 Crossref
  • 34 Scopus
prev next

Citations

Citations to this article as recorded by  Crossref logo
  • Feasibility of synthetic CT images for robotic pedicle screw planning and navigation
    Ardavan Kashtiara, Sarah Beldé, Dieter Thijs, Timo De Bondt, Johan Van Goethem, Erik Van de Kelft
    European Spine Journal.2026; 35(3): 1354.     CrossRef
  • Power-drill fluoroscopy-controlled technique as an alternative to navigation-assisted pedicle screw placement: A propensity score-matched retrospective cohort study
    Felix Corr, Faizan Kareem, Linda Bättig, Benedict Caspari, Karl Kapahnke, Silvio Heinig, Simon Behringer, Erik Schulz, Yesim Yildiz, Nader Hejrati, Oliver Bozinov, Benjamin Martens, Kern Singh, Martin N. Stienen, Stefan Motov
    Brain and Spine.2026; 6: 105959.     CrossRef
  • Spinal Robotics in Adult Spinal Deformity Surgery: Key Concepts and Technical Considerations
    Kareem Khalifeh, Carson P. McCann, Nicholas S. Hernandez, Martin H. Pham
    Asian Journal of Neurosurgery.2025; 20(03): 448.     CrossRef
  • Factors causing deviation of robot-assisted pedicle screw placement for adolescent idiopathic scoliosis: why does deviation still occur even with robotics?
    Jun Ueno, Yoshiaki Torii, Masahiro Iinuma, Atsuhiro Yoshida, Ken Tomochika, Takahiro Hideshima, Makoto Ito, Tsutomu Akazawa
    European Spine Journal.2025; 34(7): 2714.     CrossRef
  • Robotic-Guided Spine Surgery: Implementation of a System in Routine Clinical Practice—An Update
    Mirza Pojskić, Miriam Bopp, Omar Alwakaa, Christopher Nimsky, Benjamin Saß
    Journal of Clinical Medicine.2025; 14(13): 4463.     CrossRef
  • Complications and Errors With Spinal Robotics and Navigation
    Trice A. Pickens, Cade F. Bennett, Daniel E. Herrera, Wellington K. Hsu, Srikanth N. Divi, Alpesh A. Patel
    Contemporary Spine Surgery.2025; 26(9): 1.     CrossRef
  • Risk factors of inaccurate screw placement in robotic spine surgeries: why do robots make error and how to avoid them?
    S. Vidyadhara, R Dinesh Iyer, Abhishek Soni, T. Balamurugan, Dhiyanesh Krishnamurthy
    Journal of Robotic Surgery.2025;[Epub]     CrossRef
  • Risk factors analysis for pedicle screw placement deviation in robot-assisted MIS-TLIF
    Tianci Yang, Beixi Bao, Hui Yan, Yuxuan Wu, Xiaokang Cheng, Chunyang Xu, Yang Ye, Haoran Zhang, Jiaguang Tang
    BMC Surgery.2025;[Epub]     CrossRef
  • A Retrospective Cohort Study Comparing Robot-Assisted and Conventional Fluoroscopy-Guided Pedicle Screw Placement
    Hassan Seif, Emanuele Maragno, Marco Gallus, Szabolcs Szeöke, Michael Schwake
    Journal of Clinical Medicine.2025; 14(19): 6831.     CrossRef
  • Accuracy and potential risk factors of pedicle screw placement using a noninvasive-registration robotic system in the thoracolumbar spine
    Rui Yang, Kui Wang, Weilin Li, Jiajun Feng, Jian Jiang, Yuefeng Sun, Hong Wang
    Journal of Robotic Surgery.2025;[Epub]     CrossRef
  • Accuracy and risk factors of Magerl screw placement in robot‐assisted atlantoaxial surgery: A case series study
    Wu Jiayuan, Wei Yi, Duan Fangfang, He Da, Jiang Xieyuan, Tian Wei
    The International Journal of Medical Robotics and Computer Assisted Surgery.2024;[Epub]     CrossRef
  • A Single-Center Experience of Robotic-Assisted Spine Surgery in Korea : Analysis of Screw Accuracy, Potential Risk Factor of Screw Malposition and Learning Curve
    Bu Kwang Oh, Dong Wuk Son, Jun Seok Lee, Su Hun Lee, Young Ha Kim, Soon Ki Sung, Sang Weon Lee, Geun Sung Song, Seong Yi
    Journal of Korean Neurosurgical Society.2024; 67(1): 60.     CrossRef
  • Accuracy and clinical characteristics of robot-assisted cervical spine surgery: a systematic review and meta-analysis
    Jiayuan Wu, Mingxing Fan, Da He, Yi Wei, Fangfang Duan, Xieyuan Jiang, Wei Tian
    International Orthopaedics.2024; 48(7): 1903.     CrossRef
  • Feasibility and safety report on robotic assistance for cervical pedicle screw fixation: a cadaveric study
    Seungjun Ryu, Byeong-Jin Ha, Sunjin Yoon, Chang Kyu Lee, Dong Ah Shin, Keung-Nyun Kim, Seong Yi
    Scientific Reports.2024;[Epub]     CrossRef
  • Level-specific comparison of 3D navigated and robotic arm-guided screw placement: an accuracy assessment of 1210 pedicle screws in lumbar surgery
    Tomoyuki Asada, Tejas Subramanian, Chad Z. Simon, Nishtha Singh, Takashi Hirase, Kasra Araghi, Amy Z. Lu, Eric Mai, Yeo Eun Kim, Olivia Tuma, Myles R J Allen, Eric Kim, Maximilian Korsun, Joshua Zhang, Cole Kwas, James Dowdell, Sravisht Iyer, Sheeraz A. Q
    The Spine Journal.2024; 24(10): 1872.     CrossRef
  • Mazor X robot-assisted upper and lower cervical pedicle screw fixation: a case report and literature review
    Zilin Gao, Xiaobo Zhang, Zhengwei Xu, Chao Jiang, Wei Hu, Haiping Zhang, Dingjun Hao
    BMC Geriatrics.2024;[Epub]     CrossRef
  • Response to letter to the editor regarding “Level-specific comparison of 3D navigated and robotic arm-guided screw placement: an accuracy assessment of 1210 pedicle screws in lumbar surgery”
    Tomoyuki Asada, Sheeraz A. Qureshi
    The Spine Journal.2024; 24(12): 2430.     CrossRef
  • Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods
    Lu-Ping Zhou, Ren-Jie Zhang, Wen-Kui Zhang, Liang Kang, Kai-Xuan Li, Hua-Qing Zhang, Chong-Yu Jia, Yin-Shun Zhang, Cai-Liang Shen
    Neurosurgical Review.2023;[Epub]     CrossRef
  • Robotic navigation during spine surgery: an update of literature
    Qi Zhang, Xiao-Guang Han, Ming-Xing Fan, Jing-Wei Zhao, Zhao Lang, Ji-Le Jiang, Da He, Bo Liu, Wei Tian
    Expert Review of Medical Devices.2023; 20(6): 427.     CrossRef
  • Robotics in Cervical Spine Surgery: Feasibility and Safety of Posterior Screw Placement
    Lu-Ping Zhou, Zhi-Gang Zhang, Dui Li, Shu Fang, Rui Sheng, Ren-Jie Zhang, Cai-Liang Shen
    Neurospine.2023; 20(1): 329.     CrossRef
  • Effects of tracer position on screw placement technique in robot-assisted posterior spine surgery: a case–control study
    Meng Yi, Jipeng Song, Yao Zhang, Wancheng Lin, Mingtao Yao, Yuyu Fan, Lixiang Ding
    BMC Musculoskeletal Disorders.2023;[Epub]     CrossRef
  • A Novel Free‐hand Technique of Pedicle Screw Placement in the Lumbar Spine: Accuracy Evaluation and Preliminary Clinical Results
    Weiqi Jiang, Ao Leng, Lingzhi Meng, Zuoyao Long, Yu Long, Qi Wang
    Orthopaedic Surgery.2023; 15(9): 2260.     CrossRef
  • Severe Obesity Is an Independent Risk Factor of Early Readmission and Nonhome Discharge After Cervical Disc Replacement
    Tejas Subramanian, Daniel Shinn, Pratyush Shahi, Izzet Akosman, Troy Amen, Omri Maayan, Eric Zhao, Kasra Araghi, Junho Song, Sidhant Dalal, James Dowdell, Sravisht Iyer, Sheeraz Qureshi
    Neurospine.2023; 20(3): 890.     CrossRef
  • Three-Dimensional Quantitative Assessment of Pedicle Screw Accuracy in Clinical Utilization of a New Robotic System in Spine Surgery: A Multicenter Study
    Byeong-Jin Ha, Jong-Min Lee, Seon-Jin Yoon, Byung-Kwan Kim, Junseok Lee, Suhun Lee, Seungjae Ryu, Yongyeob Cha, Sungteac Hwang, Donggi Woo, Chang Kyu Lee, Dong Ah Shin, Yoon Ha, Sung Uk Kuh, Keung Nyun Kim, Dongwuk Son, Seong Yi
    Neurospine.2023; 20(3): 1028.     CrossRef
  • Assessing the Accuracy of Spinal Instrumentation Using Augmented Reality (AR): A Systematic Review of the Literature and Meta-Analysis
    Bhavya Pahwa, Tej D. Azad, Jiaqi Liu, Kathleen Ran, Connor J. Liu, Jovanna Tracz, Shahab Aldin Sattari, Jawad M. Khalifeh, Brendan F. Judy, Ali Bydon, Timothy F. Witham
    Journal of Clinical Medicine.2023; 12(21): 6741.     CrossRef
  • Spine Surgical Robotics: Current Status and Recent Clinical Applications
    Jiangtao Wang, Junxian Miao, Yi Zhan, Yongchao Duan, Yuanshun Wang, Dingjun Hao, Biao Wang
    Neurospine.2023; 20(4): 1256.     CrossRef
  • Posterior atlantoaxial internal fixation using Harms technique assisted by 3D-based navigation robot for treatment of atlantoaxial instability
    Zhao Lang, Xiaoguang Han, Mingxing Fan, Yajun Liu, Da He, Wei Tian
    BMC Surgery.2022;[Epub]     CrossRef
  • Comparison of accuracy and safety between second-generation TiRobot-assisted and free-hand thoracolumbar pedicle screw placement
    Kai Yan, Qi Zhang, Wei Tian
    BMC Surgery.2022;[Epub]     CrossRef
  • Development and Clinical Trial of a New Orthopedic Surgical Robot for Positioning and Navigation
    Jie Chang, Lipeng Yu, Qingqing Li, Boyao Wang, Lei Yang, Min Cheng, Feng Wang, Long Zhang, Lei Chen, Kun Li, Liang Liang, Wei Zhou, Weihua Cai, Yongxin Ren, Zhiyi Hu, Zhenfei Huang, Tao Sui, Jin Fan, Junwen Wang, Bo Li, Xiaojian Cao, Guoyong Yin
    Journal of Clinical Medicine.2022; 11(23): 7091.     CrossRef

Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:

Include:

Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study
Neurospine. 2021;18(4):839-844.   Published online December 31, 2021
Download Citation

Download a citation file in RIS format that can be imported by all major citation management software, including EndNote, ProCite, RefWorks, and Reference Manager.

Format:
Include:
Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study
Neurospine. 2021;18(4):839-844.   Published online December 31, 2021
Close
Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study
Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study
Potential risk factor Group A (n = 726) Group B (n = 54) p-value
Sex 0.672
 Male 328 (42.05) 26 (3.33)
 Female 398 (51.03) 28 (3.59)
Age (yr) 0.316
 ≥ 60 352 (45.13) 30 (3.85)
 < 60 374 (47.95) 24 (3.08)
Body mass index (kg/m2) 0.020
 ≥ 30 92 (11.79) 14 (1.79)
 25–30 299 (38.33) 17 (2.18)
 < 25 335 (42.95) 23 (2.95)
Bone density 0.041
 T value ≤ -2.5 326 (41.79) 32 (4.10)
 T value > -2.5 400 (51.28) 22 (2.82)
Preoperative diagnosis 0.899
 Thoracolumbar fracture 142 (18.21) 10 (1.28)
 Lumbar disc herniation 179 (22.95) 13 (1.67)
 Lumbar spinal stenosis 197 (25.26) 13 (1.67)
 Lumbar spondylolisthesis 208 (26.67) 18 (2.31)
Instrumented segment 0.929
 T10–L2 138 (17.69) 10 (1.28)
 L3–S1 588 (75.38) 44 (5.64)
Screw side 0.573
 Left 361 (46.28) 29 (3.72)
 Right 365 (46.79) 25 (3.21)
Distance between the instrumented level and tracker 0.006
 1 Level 305 (39.10) 21 (2.69)
 2 Levels 310 (39.74) 16 (2.05)
 ≥ 3 Levels 111 (14.23) 17 (2.18)
Surgical approach 0.030
 Percutaneous 432 (55.38) 24 (3.08)
 Open 294 (37.69) 30 (3.85)
Surgeons 0.634
 1st group 153 (19.62) 9 (1.15)
 2nd group 125 (16.03) 7 (0.90)
 3rd group 320 (41.03) 28 (3.59)
 4th group 128 (16.41) 10 (1.28)
Risk factor OR (95% CI) p-value
Body mass index (kg/m2)
 < 25 1.000
 25–30 0.893 (0.464–1.716) 0.734
 ≥ 30 2.459 (1.199–5.044) 0.014
Bone density
 T value > -2.5 1.000
 T value ≤ -2.5 1.857 (1.046–3.295) 0.034
Distance between the instrumented level and the tracker
 1 Level 1.000
 2 Levels 0.746 (0.380–1.465) 0.395
 ≥ 3 Levels 2.216 (1.119–4.387) 0.022
Table 1. Univariate analysis for potential risk factors of unsatisfactory screw position

Values are presented as number (%).

Group A, perfect screw positions; group B, unsatisfactory screw positions.

Table 2. Multivariate analysis for potential risk factors of unsatisfactory screw position

OR, odds ratio; CI, confidence interval.